Uitgebreide gebruiksaanwijzingen staan in de gebruikershandleiding.
F565937
POWER
TIMER
QUIET POWERFUL
ION
ALLERGEN BUSTER
Operating Instructions Air Conditioner
Indoor Unit Outdoor Unit
CS-E9HKEA CU-E9HKEA CS-E12HKEA CU-E12HKEA
ENGLISH 2~7 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. DEUTSCH 20 ~ 25 Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf. PORTUGUÊS 38 ~ 43 Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
FRANÇAIS 8 ~ 13 Avant d'utiliser l'appareil, lisez ce mode d'emploi dans son intégralité et conservez-le pour toute référence ultérieure. ITALIANO 26 ~ 31 Prima di utilizzare l'unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro. E 44 ~ 49 , .
ESPAÑOL 14 ~ 19 Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. NEDERLANDS 32 ~ 37 Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik. 50 ~ 55 , .
QUICK GUIDE / GUIDE RAPIDE GUÍA RÁPIDA / KURZANLEITUNG GUIDA RAPIDA / SNELLE GIDS GUA RÁPIDO / YNTOMO OHO
© 2007 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
DEFINITION The instructions to be followed are classified by the following symbols:
This symbol denotes an action that is PROHIBITED. These symbols denote actions that are COMPULSORY.
To prevent personal injury, injury to others, or property damage, please observe the following. Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classified as below:
Warning This sign warns of death or serious injury. This sign warns of Caution injury or damage to property.
Remote Control · Do not use rechargeable (Ni-Cd) batteries. · Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries. · Remove the batteries if the unit is not going to be used for a long period of time. · New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
Indoor Unit · Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work. · Do not insert your fingers or other objects into the unit. · Do not attempt to repair the unit by yourself.
Air inlet
Indoor Unit · Do not install the unit in a potentially explosive atmosphere. · Do not wash the unit with water, benzene, thinner or scouring powder. · Do not use for other purposes such as preservation of food. · Do not use any combustible equipment in front of the airflow outlet. · Do not expose directly to cold air for a long period. · Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur. · Aerate the room regularly. Power Supply · Do not pull the cord to disconnect the plug. · Switch off the power supply and unplug before cleaning or servicing. · Turn off the power supply and unplug if the unit is not used for a long period of time. · This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the air conditioner during lightning, it may cause electric shock. Outdoor Unit · Do not sit, step or place anything on the unit. · Do not touch the sharp aluminium fin. · Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur. · After long periods of use, make sure the installation rack is not damaged.
Power Supply · Do not share the same power outlet with other equipment. · Do not modify power cords. · Do not use extension cords. · Do not operate with wet hands. · Do not operate or stop the unit by inserting or pulling out the power plug. · Insert the power plug properly. · Use the specified supply cord. · If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. · Dust on the electric power plug should be periodically wiped with a dry cloth. · This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock or fire in case of malfunction. · In case of emergency or abnormal conditions (burnt smell, etc), turn off the power supply and unplug, and consult your nearest dealer.
Air outlet
Air inlet Air inlet
Air outlet
Outdoor Unit · Do not insert your fingers or other objects into the unit. 2
REGULATORY INFORMATION REGULATORY INFORMATION
The appliance is not intended for use by young children or the infirm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.
Thank you for purchasing Air Conditioner
TABLE OF CONTENTS SAFETY PRECAUTIONS REGULATORY INFORMATION 2 3
OPERATION CONDITION
Use this air conditioner under the following temperature range Temperature (°C) Indoor *DBT *WBT 32 23 16 11 30 16 Outdoor *DBT *WBT 43 26 -15 24 18 -10 -
Maximum COOLING Minimum Maximum HEATING Minimum * DBT: Dry bulb temperature * WBT: Wet bulb temperature NOTICE: · This unit is still able to operate as a cooler with outdoor temperature as low as -15°C in a non-living room, such as a computer room, with a room temperature of 16°C or above, and room humidity up to 80%. When the outdoor temperature drops to -15°C, compressor will be cut off and resume operation again once the temperature rises to more than -15°C. · When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly and outdoor unit might stop for protection control. Replacement or installation of power plugs shall be performed by authorized/ qualified personnel only. The wires in this mains lead are coloured in accordance with the following code:
Terminals
Red Black Green/Yellow
PRODUCT OVERVIEW & OPERATIONS CARE & CLEANING TROUBLESHOOTING
4~5 6 7
QUICK GUIDE BACK COVER
NOTE : The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
wires live neutral earth
colours (GB Standard) brown blue green-yellow
Wiring colour may vary depending on a country wiring code's standard. ENVIRONMENTAL REQUIREMENTS Battery Disposal The batteries must be recycled or disposed of properly. END-OF-LIFE DISPOSAL "Instructions for end-user" for air conditioners: This air conditioner bears the above mark, indicating that electrical equipment should not be disposed of alongside general household waste. European Community countries (*), should have a dedicated collection system for these products. Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment as a result of incorrect waste handling. This dismantling and disposal of refrigerant, oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery and should not be disposed of in the municipal waste stream. Please contact your installer, dealer or local authority for more information. Penalties may also be applicable for incorrect disposal of waste products, in accordance with national legislation. *subject to the national law of each member state Information on Disposal in other countries outside the European Union This symbol is only valid in the European Union. If you wish to discard this product, please contact your installer, dealer or local authority and ask for the correct method of disposal. · Do not switch ON the unit when waxing the floor. After waxing, aerate the room properly before operating the unit. · Do not install the unit in oily and smoky areas.
3
ENGLISH
PRODUCT OVERVIEW & OPERATIONS PRODUCT OVERVIEW & OPERATIONS
Ionizer Supersonic air purifying device Do not touch during operation. Auto OFF/ON button · Used when remote control is misplaced or malfunction. Step Action Mode 1 Press once. Automatic Press and hold until you Force 2 hear one beep, then release. cooling Repeat step 2. Press and Normal 3 hold until you hear two cooling beeps, then release. Repeat step 3. Press and Force 4 hold until you hear three heating beeps, then release. Press the button to turn off.
Front panel
Air filter
Airflow direction louver · Do not adjust by hand.
Receiver
INDICATOR
s: 1 0m
imu
md
ista
nce
(Green) (Orange) (Orange) (Green) (Green)
(Blue)
Max
OFF/ON
TO TURN ON OR OFF THE UNIT
· Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly. Remote control display
AUTO HEAT COO L DRY ION
TEMP
TO SET TEMPERATURE
FAN SPEE D AIR SWIN G
MOD E QUIE
OFF/O
N
ion
· Selection range: 16°C ~ 30°C. · Operating the unit within the recommended temperature could induce energy saving. HEAT mode : 20°C ~ 24°C. COOL mode : 26°C ~ 28°C. DRY mode : 1°C ~ 2°C lower than room temperature.
MODE
T
POW ERFU
L
TEM P
TO SELECT OPERATION MODE
FAN S
PEED
TIME R ON 1
AIR S
WING
SET 2 3 CAN CEL
RC
AUTO mode - For your convenience · Unit selects operation mode every 30 minutes according to temperature setting, outdoor and room temperature. During operation mode selection the power indicator blinks. HEAT mode - To enjoy warm air · Unit takes a while to warm up. The power indicator blinks during this operation. COOL mode - To enjoy cool air DRY mode - To dehumidify the environment · Unit operates at low fan speed to give a gentle cooling operation.
OFF
SET CHE CK CLO CK
AC
RES ET
INVE
RTE R
4
· To turn ON or OFF the unit at a preset time.
ON
· For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)
1 OFF
2
TIMER
SET
Select ON or OFF timer.
Set the time.
ON
Confirm. or then
· Keeps the room ventilated. · If AUTO is set, the louvers swing left/right and up/down automatically. · In heat mode, the air blows horizontally for a while, then starts to blow downwards and the airflow louvers start to swing left/right after the temperature rises. TO ENJOY CLEAN AIR · To provide fresh air effect by producing negative ions. - Ion operation could be activated independently. OFF/ON Press to stop the operation. TO ENJOY QUIET ENVIRONMENT · This operation reduces airflow noise.
QUIET POWERFUL
· To cancel ON or OFF timer, press press CANCEL .
OFF
· When ON Timer is set, the unit may start earlier (up to 30 minutes) before the actual set time in order to achieve the desired temperature on time. · Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. · If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is SET resumed) by pressing .
TO ACHIEVE TEMPERATURE QUICKLY
OPTIONAL SETTINGS
Press and hold for 5 seconds to dim or restore the unit's indicator brightness. Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press and hold for approximately 5 seconds to show 12-hour (am/pm) or 24-hour time indication. Press to restore the remote control's default setting. Not used in normal operations.
CLOCK
RC
· Supersonic air purifying device (super alleru-buster) operates automatically once the unit is switched on. · , and can be activated in all modes and can be cancelled by pressing the respective button again.
QUIET POWERFUL QUIET POWERFUL
RESET
,
SET
AC RESET
Set the temperature 1°C higher in cool mode or 2°C lower in heat mode than the desired temperature to achieve a 10% power saving. Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. 5
·
and same time.
can not be selected at the
ENGLISH
FAN SPEED
TO SELECT FAN SPEED (5 OPTIONS)
TO SET THE TIMER
CARE & CLEANING
CAUTION · Switch off the power supply and unplug before cleaning. · Do not touch the aluminium fin, sharp parts may cause injury. HINTS · Clean the filter regularly for best performance and to reduce power consumption. · Please consult your nearest dealer for seasonal inspection.
WASHING INSTRUCTION ...