Uitgebreide gebruiksaanwijzingen staan in de gebruikershandleiding.
R
AY -AP18DR AY -AP24DR AH -AP18DR AH -AP24DR
AY-AP18DR AY-AP24DR AH-AP18DR AH-AP24DR
AE -A18DR AE -A24DR AU-A18DR AU-A24DR
OPERATION MANUAL BEDIENUNGSANLEITUNG NOTICE D'UTILISATION MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONE MANUAL DE INSTRUÇÕES GEBRUIKSAANWIJZING
NEDERLANDS PORTUGUÊS
INDOOR UNIT ZIMMERGERÄT UNIT INTERIEURE UNIDAD INTERIOR UNITA' INTERNA UNIDADE INTERIOR BINNEN-UNIT
OUTDOOR UNIT AUSSENGERÄT UNIT EXTERIEURE UNIDAD EXTERIOR UNITA' ESTERNA UNIDADE EXTERIOR BUITEN-UNIT
ITALIANO
· Uses ozone layer friendly refridgerant R410A. · Verwendet das die Ozonschicht schonende Kühlmittel R410A. · Utilise un réfrigérant qui n'attaque pas la couche d'ozone, le R410A. · Utiliza refrigerante R410A que no daña la capa de ozono. · Utilizza il refrigerante R410A che non danneggia il buco nell'ozono. · Usa refrigerante R410A amigo da camada de ozono. · µ R410A µ . · Gebruikt de ozon-vriendelijke koelvloeistof R410A.
SPLIT TYPE ROOM AIR CONDITIONER ZWEITEILIGES KLIMAGERÄT CLIMATISEUR INDIVIDUEL EN DEUX PARTIES ACONDICIONADOR DE AIRE DE DOBLE SERVICIO CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT AR CONDICIONADO DE DUAS UNIDADES SPLIT SPLIT-AIRCONDITIONER
ESPAÑOL FRANÇAIS DEUTSCH
ENGLISH
ENGLISH
Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product.
CONTENTS
· PRECAUTIONS ........................................... E-1 · ADDITIONAL NOTES ON OPERATION ..... E-3 · TIPS ON SAVING ENERGY ........................ E-3 · PART NAMES .............................................. E-4 · USING THE REMOTE CONTROL .............. E-6 · TIPS ABOUT PLASMACLUSTER OPERATION . E-7 · BASIC OPERATION .................................... E-8 · ADJUSTING THE AIR FLOW DIRECTION . E-10 · PLASMACLUSTER OPERATION ...... · ONE-HOUR OFF TIMER .................... · TIMER OPERATION ........................... · AUXILIARY MODE ............................. · MAINTENANCE .................................. · OPTION KIT ........................................ · BEFORE CALLING FOR SERVICE ... E-11 E-11 E-12 E-14 E-14 E-15 E-16
WARNINGS FOR USE
1 2 3 4 5 6 7 8
Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord can result in damage to the unit and cause electrical shock. Be careful not to expose your body directly to the outlet air for a long time. It may affect your physical conditions. When using the air conditioner for infants, children, elderly, bedridden, or disabled people make sure the room temperature is suitable for those in the room. Never insert objects into the unit. Inserting objects can result in injury due to the high speed rotation of internal fans. Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe, water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause electric shock. If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation immediately and turn the circuit breaker OFF. Follow local rules and regulations for power supply cord cabling. Improper cable connection can cause the power supply cord, plug and the electrical outlet to overheat and cause fire. Use only the manufacture-specified power cord for replacement. Replacement should be performed by a qualified technician or a service person.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
· Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the installation/removal/repair of the unit. This equipment complies with the requirements of Directives 89/336/EEC and 73/23/ EEC as amended by 93/68/EEC.
E-1
ENGLISH
PRECAUTIONS
PRECAUTIONS
CAUTIONS FOR USE
periodically to 1 Open a window or door ventilation may ventilate the room, especially when using gas appliances. Insufficient cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an extended period of time. 4 Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place. put anything on 5 Do notor drop, causing the outdoor unit nor step on it. The object or the person may fall down injury. designed use for 6 This unit isgreenhousefor residential use.orDo notplants. other applications such as in a kennel or to raise animals grow on the unit. If water 7 Do not place a vessel with watercause electric shock.penetrates into the unit, electrical insulations may deteriorate and not block 8 Dotroubles. the air inlets nor outlets of the unit. It may cause insufficient performance or the operation turn the circuit breaker off before 9 Be sure to stop cleaning. A fanandrotating inside the unit and you mayperforming any maintenance or is get injured. 10 Do not splash or pour water directly on the unit. Water can cause electrical shock or equipment damage. 11 This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
· Make sure to connect the air conditioner to power supply of the rated voltage and frequency. Use of a power supply with improper voltage and frequency can result in equipment damage and possible fire. · Do not install the unit in a place where inflammable gas may leak. It may cause fire. Install the unit in a place with minimal dust, fumes and moisture in the air. · Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting of the room, furniture etc. · Make sure a leak breaker or a circuit breaker is installed, depending on the installation location, to avoid electrical shock.
E-2
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. OUTDOOR TEMP. upper limit COOLING lower limit HEATING
(AY-AP18DR/AYAP24DR only)
upper limit lower limit W.B. = Wet-bulb
32°C 23°C 21°C 15°C 27°C
D.B. W.B. D.B. W.B. D.B.
20°C D.B. -
43°C D.B. 21°C D.B. 24°C D.B. 18°C W.B. -8.5°C D.B. -9.5°C W.B.
· The built-in protective device may prevent the unit from operating when used out of this range. · Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.
D.B. = Dry-bulb
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.
NOTES FOR MODELS AY-AP18DR/AY-AP24DR PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
· When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating. · After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
HEATING EFFICIENCY
· The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency. · If the heating efficiency is reduced due to low outside temperatures, use an additional heater. · It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
· Setting the thermostat 1°C higher than the desired temperature in the COOL mode (and 2°C lower in the HEAT mode with models AY-AP18DR/AY-AP24DR) will save approximately 10 percent in power consumption. · Setting the temperature lower than necessary during cooling operation will result in increased power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
· Blocking direct sunlight during cooling operation will reduce power consumption. · Close the windows and doors during cooling operation (and heating operation with models AY-AP18DR/AYAP24DR).
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME
· The indoor unit still consumes a small amount of power when it is not operating.
E-3
ENGLISH
PART NAMES
INDOOR UNIT
1 2 3 4 5 6 7 8 9 0 q w 1 Inlet (Air) 2 Open Panel 3 AUX. Button 4 Air Filters 5 Receiver Window 6 Louvre Unit
Open to clean the inside of the air conditioner.
7 Power Supply Cord
(AY-AP18DR/AH-AP18DR only)
8 Indicator Panel 9 Vertical Adjustment Louvres 0 Horizontal Adjustment Louvres q Outlet (Air) w Remote Control e AUTO FAN SPEED Lamp (green )
e r t y u
r FAN SPEED Lamp (green t PLASMACLUSTER Lamp (blue, green) y TIMER Lamp (orange u OPERATION Lamp (red ) )
)
OUTDOOR UNIT
i o p i Inlet (Air) o Refrigerant Tube and Interconnecting Cord p Drainage Hose a Outlet (Air)
a
NOTE: Actual units might vary slightly from those shown above.
E-4
REMOTE CONTROL
1 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 ON/OFF Button
MODE
TEMP.
2 4 THERMO. (Thermostat) Button 5 DISPLAY Button
FAN
TIMER TEMP.
3
6 MODE Button 7 TIMER ON Button (for setting the timer)
4
8 ONE-HOUR OFF TIMER Button 9 TIMER OFF Button (for setting the timer) 0 FAN Button q TIMER CANCEL Button w SWING Button e PLASMACLUSTER Button
ENGLISH
DISPLAY MODE 1h FAN SWING CANCEL
5 6 7 8 9 0 q w e
(The heat mode symbol is provided only on models AY-AP18DR/AY-AP24DR)
L.C.D. REMOTE CONTROL DISPLAY
r MODE SYMBOLS : AUTO : COOL : HEAT
(only for AY-AP18DR/AY-AP24DR)
y u i r
: DRY
: FAN ONLY
t FAN SPEED SYMBOLS : AUTO : Manual setting
y PLASMACLUSTER SYMBOL u TEMPERATURE AND TIMER COUNT DOWN INDICATOR i TRANSMITTING SYMBOL o TIMER ON/TIMER OFF INDICATOR
Indicates when timer on or timer off is set.
t
o
(The heat mode symbol is provided only on models AY-AP18DR/AY-AP24DR)
E-5
USING THE REMOTE CONTROL
LOADING BATTERIES Use two size-AAA (R03) batteries.
battery 1 Remove thecontrol. cover at the back of the remote
2 Insert batteries in the compartment, making sure the ± and -- polarities are
correctly aligned. · Lines will be indicated on the display when batteries are properly installed.
3 Reinstall
NOTES:
the battery cover.
Battery cover
· The battery life is approximately one year in normal use. · When you replace the batteries, always change both batteries, and make sure they are the same type. · If the remote control does not operate properly after replacing the batteries, take out the batteries and reinstall them again after 30 seconds. · If you will not be using the unit for a long time, remove the batteries from the remote control.
HOW TO USE THE REMOTE CONTROL
Point the remote control towards the unit's signal receiver window and press the desired button. The unit generates a beep when it receives the signal.
· Make sure there is no curtain or other object between the remote control and the unit. · The remote control can send signals from up to 7 metres away.
CAUTION
· Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. · Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal. · The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room. · Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.
E-6
TIPS ABOUT PLASMACLUSTER OPERATION
The ionizer inside the air conditioner will release cluster ions, which are collective mass of positive and negative ions, into the room. The cluster ions reduce airborne mold fungus.
Ionizer Cluster ions Mold fungus
AIR CLEAN OPERATION
Cluster ions released into the air will reduce airborne mold fungus.
ION BALANCE OPERATION
It is said that plenty of negative ions exist in places such as waterfalls or waterside in natural environment. In this operation mode, negative ions will be released in an increased rate, in order to bring the room air close to this condition. Please refer to page 11 for operation.
E-7
ENGLISH
BASIC OPERATION 1
Press the MODE button to select the operation mode.
AUTO HEAT COOL DRY FAN ONLY
HEAT ( is ...